DEVELOPMENT OF 100 MW GAS TURBINE SHAFT SLEEVE PULLER

Authors

  • EG Sadjere Niger Delta Development Commission, 167 Aba Road, Port Harcourt, Nigeria.
  • GO Ariavie Department of Mechanical Engineering, University of Benin, Nigeria.
  • PO Ebunilo Department of Mechanical Engineering, University of Benin, Nigeria.

DOI:

https://doi.org/10.4314/njt.313.580

Keywords:

shaft sleeve puller, turbine generator, pull-out/pull-in turbine generator, refurbishment, statistically

Abstract

A Shaft Sleeve Puller was developed, designed and constructed in response to the need to pull-out / pull-in the 30-tonnes by 12m long rotor of the 100-MW gas turbine generator for inspection, as part of a refurbishment programme of a Steel company in Delta State, Nigeria. The design is a runway system, consisting of a platform incorporating rails on which the carriages run as they bear the rotor being pulled with a pulling jack. We utilized statically determinate approach to design the platform to very high flexural rigidity to avoid deflection, a necessary condition, to prevent damage to the generator field winding. The design was successful; the system constructed and used to pull-out/pull-in six rotors of the gas turbine generators; and is still being stored for further use when the need arises.

Downloads

Issue

Section

Research papers of General Interest

How to Cite

DEVELOPMENT OF 100 MW GAS TURBINE SHAFT SLEEVE PULLER. (2012). Nigerian Journal of Technology, 31(3), 383-392. https://doi.org/10.4314/njt.313.580